Northshore Generators · Northshore Louisiana
Turnkey Whole Home Generator Installation in St. Tammany Parish
Keep your home powered through hurricanes, tropical storms, and Gulf Coast grid failures. A professionally installed standby system starts automatically within seconds of an outage.
Serving Covington, Mandeville, Slidell, Madisonville, Abita Springs, Folsom, Lacombe and surrounding St. Tammany Parish communities.
Request a Written Estimate
Share your project details and we respond within one business day.
Prefer to talk now? Call 985-239-5996
Owner Resource & Planning Hub
Calculators, pricing, permits, and fuel data for Northshore homeowners.
Calculate Your Required Generator Size & Ballpark Cost
Use our interactive three step electrical load tool to input your square footage and appliances to see exactly what size unit your property demands.
Open sizing calculatorThe St Tammany Generator Pricing Guide
See transparent numbers breaking down the actual equipment costs versus local permitting, concrete pad pouring, and electrical hookup fees.
View cost breakdownSt Tammany Parish Setback & Building Codes
Avoid expensive compliance mistakes. Read the strict local rules regarding property lines, windows, raised homes, and fire safety.
Read permit guideStandby Generator Fuel Consumption Chart
Review exact natural gas and liquid propane burn rates under half and full load capacities for 22kW and 24kW units.
View fuel chart
The Turnkey Advantage
One coordinated install from permit pull to final startup.

Site Preparation & Elevated Pads
Lot grading, setback planning, and elevated concrete pads sized for St. Tammany flood zones and coastal wind.

Transfer Switch & Code Compliance
Whole home automatic transfer switches, load management, and parish inspection ready electrical scope.

Natural Gas Line Coordination
Licensed gas line runs, meter sizing, pressure testing, and utility coordination through final startup.
St. Tammany Code Compliance
We strictly adhere to local parish setback codes (20 feet from buildings, 5 feet from property lines) and guarantee Precise Electrical Load Sizing. Our automatic transfer switches are wired to prevent dangerous utility grid backfeeding during outage restoration.
Northshore Generators documents every scope for parish and municipal inspection in St. Tammany Parish so your install passes the first time.

Hyper local setback & life safety requirements
- Building envelope setbacks: We follow parish setback rules (20 feet from buildings and 5 feet from property lines) and place every unit outside the 5 foot restriction zone that applies to soffit vents, dryer exhaust terminations, and brick weep holes so exhaust and intake air cannot short cycle into hidden wall cavities.
- Raised homes: On elevated Northshore properties, we confirm crawl spaces are properly sealed when the generator pad sits within 5 feet of the structure to prevent natural gas from collecting in under floor cavities on pilings and flood zone foundations.
- HVAC intake separation: Turnkey scope includes verifying the 10 foot clearance required between generator exhaust discharge and central air conditioning intake vents before final inspection.
- Carbon monoxide protection: We coordinate installation of code mandated hardwired carbon monoxide detectors in all sleeping areas when your scope requires it, per Louisiana residential safety standards for fuel burning appliances.
Precise Electrical Load Sizing
HVAC tonnage, well pumps, and critical circuits are documented so your 22kW Generac Guardian or Kohler package is sized correctly the first time.
Setback compliance
Pad location is surveyed against property lines, building faces, and the 5 foot buffer for soffit vents, dryer exhausts, and weep holes, documented on your permit package before concrete is poured.
Safe ATS wiring
Listed automatic transfer switches isolate utility power during generator operation with no backfeeding into Entergy lines.
Dedicated Coverage Across the Northshore
We install exclusively in St. Tammany Parish. Our crews know local AHJ requirements, inspection windows, and HOA standards in your subdivision.
Covington
ZIP 70433, 70434, 70435From municipal permitting in Covington to neighborhood covenants in communities such as Tchefuncta Club Estates, Riverwood, TerraBella Village, and others. We document setbacks, noise ordinances, and utility clearances before we pour concrete.
View Covington generator installation →Mandeville
ZIP 70448, 70471From municipal permitting in Mandeville to neighborhood covenants in communities such as The Sanctuary, Beau Chêne, Beau Rivage, and others. We document setbacks, noise ordinances, and utility clearances before we pour concrete.
View Mandeville generator installation →Slidell
ZIP 70458, 70460, 70461From municipal permitting in Slidell to neighborhood covenants in communities such as Lake Village, Breckenridge, Meadow Lake, and others. We document setbacks, noise ordinances, and utility clearances before we pour concrete.
View Slidell generator installation →Madisonville
ZIP 70447From municipal permitting in Madisonville to neighborhood covenants in communities such as Guste Island, Bedico Creek, Del Oaks, and others. We document setbacks, noise ordinances, and utility clearances before we pour concrete.
View Madisonville generator installation →Abita Springs
ZIP 70420From municipal permitting in Abita Springs to neighborhood covenants in communities such as Hillcrest, Abita Academy, Harrison Springs, and others. We document setbacks, noise ordinances, and utility clearances before we pour concrete.
View Abita Springs generator installation →Folsom
ZIP 70437From municipal permitting in Folsom to neighborhood covenants in communities such as Lee Lane area, Savannahs, rural acreage estates, and others. We document setbacks, noise ordinances, and utility clearances before we pour concrete.
View Folsom generator installation →Lacombe
ZIP 70445From municipal permitting in Lacombe to neighborhood covenants in communities such as Cypress Bayou, Lakeview Drive waterfront, Oak Lawn, and others. We document setbacks, noise ordinances, and utility clearances before we pour concrete.
View Lacombe generator installation →
St. Tammany Parish permitting expertise: We file electrical, mechanical, and gas scope with the parish and applicable city offices in Covington, Mandeville, Slidell, Madisonville, Abita Springs, Folsom, Lacombe, so your project stays inspection ready without revision loops.
Transparent Installation Costs: No Surprise Line Items
Every Northshore property is different. We walk your site and deliver a written estimate that itemizes equipment, labor, and permitting. See our full pricing breakdown before you commit.
Generator capacity
Larger homes, dual HVAC, and well pumps often require 22kW Generac Guardian or 24kW Generac Guardian packages versus smaller standby units.
Gas line run distance
Longer trenching from the meter to the pad, boring under drives, and regulator upgrades add material and labor.
Permitting & inspections
St. Tammany Parish and individual municipalities (Covington, Mandeville, Slidell, Madisonville) each carry distinct fee and inspection schedules.
Electrical panel & switch gear
Main panel age, available breaker spaces, and whether you need a service upgrade or load shedding module affect total scope.
Talk through your home's loads and get a real installation cost, usually on the first call.
Call 985-239-5996St. Tammany Parish service area
Northshore Generators operates across the Northshore from our regional service centroid—covering every primary install hub below.
Regional headquarters centroid
- Latitude:
- 30.4755° N
- Longitude:
- -90.1009° W
Primary phone
985-239-5996Primary service hubs
Map data © OpenStreetMap contributors